Measure intelligently

What Is TDS in Drinking Water? PPM, Meters & RO Rejection

A TDS meter is excellent for one job: tracking dissolved-ion trends. It is a poor substitute for a water-quality test.

What TDS actually means

Total dissolved solids (TDS) is a broad measure of dissolved material in water. In domestic water discussions it is usually expressed in mg/L or ppm. Calcium, magnesium, sodium, bicarbonate, chloride and sulphate can all contribute. The number does not tell you which of them are present.

What a pocket TDS meter really measures

Most inexpensive “TDS meters” measure electrical conductivity. Dissolved ions carry electrical current; the meter applies a conversion factor to estimate TDS. That is why two meters can display somewhat different ppm values for the same water even when neither is broken.

What TDS cannot tell you

It cannot identify lead, nitrate or arsenic. It cannot prove that PFAS are absent. It cannot establish microbiological safety. Many organic substances contribute little to conductivity. “8 ppm” therefore does not mean “8 ppm of contaminants”, and “0 ppm” should never be presented as proof of pure or safe water.

Calculate RO rejection

Example: 95.0% rejection.

The calculation is: (feed TDS − product TDS) ÷ feed TDS × 100. A 300 ppm feed and 15 ppm permeate gives 95% apparent rejection.

How to take a more useful reading

  1. Use the same meter for feed and product water.
  2. Let the RO system reach normal operating condition after installation/filter changes.
  3. Use clean containers and avoid cross-contamination.
  4. Allow temperature compensation/stabilisation if the meter supports it.
  5. Record a trend, not one dramatic reading.

Why a remineralised system can confuse the test

If you measure after a remineralisation cartridge or mineral-dosing stage, the system has deliberately added ions after the membrane. That reading cannot be used directly as membrane permeate for rejection calculations. Measure before remineralisation if the manufacturer provides a safe sampling point, or use the system's specified diagnostic method.

When a rising TDS deserves attention

A sustained deterioration in rejection can point to membrane wear, damage, poor sealing, pressure changes or another system issue, but diagnose it using the manufacturer's troubleshooting procedure. One warm-water reading or an inexpensive meter is not enough to condemn a membrane.

Sources and further reading

For factual claims that matter to health, regulation or product performance, we prefer primary and official sources. Useful references for this guide include:

Last reviewed: 6 October 2026. This guide is written for a UK audience. Always follow current supplier, regulator, manufacturer and healthcare advice where it applies.